Safe, robust and AREI-compliant electrical installations for business premises, charging plazas and industrial sites.

 

Schedule a technical consultation

Electrotechnics for charging infrastructure and business installations

Every charging station, battery, PV installation or EMS starts with a solid electrical foundation. Powerland designs, builds and inspects electrotechnical installations that distribute your power reliably and are ready for growth.

Electrical challenges? We deliver stability.

Challenges

  • Insufficient capacity for charging points
  • Outdated distribution boardsn
  • Unclear cable sections and protection
  • Risk of peak loads from new consumers
  • Complex cabling in existing buildings
  • Uncertainty about inspection and compliance (AREI)

Solutions

  • Correct dimensioning of cables and power capacity
  • Upgrade or expansion of distribution boards
  • Integration with EMS for smart control
  • Low and medium voltage solutions
  • Full AREI-compliant installation and inspection
  • Safe preparation for charging plazas and energy projects

From distribution boards to connections: your electrical backbone

Low voltage installations

Low voltage installations

  • Cable dimensioning
  • Fuses and protections
  • Connections to charging points and building
Medium voltage connections

Medium voltage connections

  • New transformer cabins
  • Adapting metering cells and transformation in existing cabins
  • Larger charging plazas with separate metering cabin and transformer cabin
Verdeelborden en bordenbouw

Distribution boards and panel construction

  • New switchboards
  • Modification of existing distribution boards
  • Power distribution ready for future consumption
  • Grid disconnection panels
  • Remote control

Cabling that is ready for today and tomorrow

Cable routes and connections

  • Correct cable sections per charging point
  • Underground and above-ground routes
  • Protection against moisture, heat and mechanical damage
  • Integration via conduit, cable tray or trench
  • Connections to AC and DC charging stations

Connection capacity and protection

  • Analysis of available capacity
  • Load balancing between charging points
  • Overload protection
  • Smart power distribution via EMS
Contact us
Beschrijving

Dimensioned for today's capacity, with reserve capacity for tomorrow's expansion.

How does the electrotechnics installation process work?

Analysis & dimensioning

Mapping the installation, consumption and growth plans.

Design & engineering

Determining cable sections, protections and panel modifications.

Execution & connection

Installation and connection by certified technicians.

Configuration & inspection

Testing, labelling and AREI-compliant inspection.

 

Handover & monitoring

Diagrams, certificates and connection to EMS or charge management.

 

From the first power analysis to the final AREI inspection: Powerland guides every electrotechnical project throughout Belgium. You receive a complete handover file with single-line diagrams, layout diagrams, cable and protection calculations and inspection certificates — aligned with insurance requirements and, if desired, linked to your energy management system.

Plan your installation project

Questions about
electrical engineering

Yes. For larger sites we take care of the complete medium voltage preparation.

This depends on distance, power and type of charging point. We fully dimension this according to AREI.

The key threshold is 30 kVA total installed AC inverter capacity (Smax) of the entire installation. All inverters count together (PV, battery, hybrid, V2G, ...).

Up to and including 30 kVA: no external grid disconnect relay needed

For installations ≤ 30 kVA, the integrated automatic disconnection system of the inverter(s) is sufficient, provided the inverter(s) are homologated and appear on the Synergrid C10/26 list.

Above 30 kVA: external grid disconnect relay mandatory

For installations with total AC inverter capacity > 30 kVA, an external grid disconnect panel with a homologated grid disconnect protection relay is required. The relay must appear on the Synergrid list C10/21 or (where applicable) C10/23.

Important: capacities are added together.

You add up all inverters, for example 20 kVA PV + 20 kVA battery = 40 kVA total → external grid disconnect panel with relay C10/21/C10/23 mandatory.

To all questions  

Contact and help

Our customer service and sales team are ready to assist you.
If you are at a charging point and require immediate assistance, you can reach us at +32 57 69 01 05 to speak to an employee.
For non-urgent questions regarding billing or your account, you can email info@powerland.be

Get in touch